There is an approved document guidance available from the builders hardware industry federation bhif hardware for fire and escape doors.
Fire escape door width uk.
Design for vertical escape 28 introduction 28 number of escape stairs 28 provision of refuges 29 width of escape stairs 30.
A door or doorway is the clear width when the door is open see diagram c1.
All doors are of a high level of security at competitive prices.
An escape route is the width at 1 500 mm above floor level when defined by walls or elsewhere the minimum width of passage available between any fixed obstructions.
Metric sized internal doors are becoming increasingly popular and are now commonly used in scotland and europe.
Fire detection and alarm systems 9 design and installation of systems 11 section 2.
The area of walls doors and windows permitted to have reduced or undetermined fire resistance known as unprotected areas will be dependent on how close these elements are to the boundary.
When replacing any window the opening should be sized to provide at least the same potential for escape as the window it replaces.
It is important that each floor plan of a building indicates the shortest route s to a place of comparative or ultimate safety should an emergency evacuation be triggered e g.
By the sounding of the fire alarm.
Fire door standard sizes.
Design for horizontal escape 12 introduction 12 escape route design 12 residential care homes 25 section 3.
Fire exit doors are the final door on an emergency exit route that must lead to a place of safety.
Issue 4 2012 detailing the requirements for any fixtures and fittings used with fire doors and fire.
This is because extra core component materials are required in the construction of the door to achieve its fire rating.
Meet your fire exit door requirements with our custom made range of steel fire exit doors.
The width of final exit doors and the escape routes leading to them will dictate the maximum number of people who can safely occupy.
Common options are 2040 x 526 626 726 826 926 x 40mm.
Widths of escape routes and exits minimum width for an escape route should ideally be 1050mm but in any case not less than 750mm and where wheelchair users are likely to use it not less than 900mm.
All of the standard uk and metric door sizes are usually available as a fire door equivalent with the only difference being an increased door thickness of 45mm.
The main difference between these and the standard uk sizes above are an increased door height of 2040mm and door thickness of 40mm.